1.
China Journal of Orthopaedics and Traumatology ; (12): 75-79, 2022.
Article in Chinese | WPRIM | ID: wpr-928270

ABSTRACT

Developmental dysplasia of the hip (DDH) is a major cause of hip arthritis and ultimately total hip arthroplasty. Due to the dysplastic acetabulum, how to place the acetabular cup becomes a challenge in acetabular reconstruction for such patients. Especially in the acetabula classified as Crowe typeⅡand type Ⅲ, the dislocation of the femoral head causes bone defects above the true acetabulum, which will affect the stability of the acetabular cup when the acetabular reconstruction is performed at the true acetabulum. Many acetabular reconstruction methods such as bone grafting, the use of small acetabular cups, socket medialization technique, and high hip center technique are used to increase the host bone coverage of the cup. However, each method has its own shortcomings that can not be ignored so that there is no unified conclusion on the acetabular reconstruction methods for Crowe typeⅡand type Ⅲ hip dysplasia. This article summarized and evaluated various reconstruction methods in combination with the acetabular morphology of DDH, and put forward the research direction in the future.


Subject(s)
Humans , Acetabulum/surgery , Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Hip Dislocation/surgery , Hip Dislocation, Congenital/surgery , Hip Prosthesis , Treatment Outcome
2.
China Journal of Orthopaedics and Traumatology ; (12): 985-990, 2021.
Article in Chinese | WPRIM | ID: wpr-921929

ABSTRACT

Osteoarthritis(OA) is one of the most common joint diseases. As Chinese society enters the age of aging, the incidence of OA has been soar year by year, and research on its pathogenesis has been continuously valued by researchers. Studies have found that inflammatory cytokines, mainly interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α), were responsible for the construction of OA inflammatory networks. It was also found that the overexpression of proteases, mainly matrix metalloproteinases(MMPs) and a disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS), was the direct cause of OA cartilage deficiency. What's more, signaling pathways such as stromal cell derived factor-1 (SDF-1) and Wnt, chondrocytic senescence and the senescence-associated secretory phenotype (SASP), chondrocyte apoptosis and autophagy, and estrogen all play significant roles in OA pathogenesis. This paper extensively reviews the research literature relevant to the pathogenesis of OA in recent years, and systematically expounds the pathogenesis of OA from two aspects:molecular level and cell level. At the end of the paper, we discussed and predicted some potential directions in the future clinical diagnosis and treatment of OA.


Subject(s)
Humans , Cartilage , Cartilage, Articular , Chondrocytes , Interleukin-1beta , Osteoarthritis/genetics , Signal Transduction , Tumor Necrosis Factor-alpha
3.
China Journal of Orthopaedics and Traumatology ; (12): 1096-1099, 2018.
Article in Chinese | WPRIM | ID: wpr-776169

ABSTRACT

OBJECTIVE@#To analyze the relationship among the parameters by measuring the relevant parameters of the anteroposterior X-ray of both hips in patients after total hip arthroplasty, to discuss the reliable anatomical markers and reference standards of acetabulum placement in total hip arthroplasty, and finally to accurately control the abduction angle of acetabulum.@*METHODS@#From January 2016 to June 2017, 282 patients (235 hips) underwent total hip arthroplasty and 128 patients(157 hips) met the inclusion criteria. There were 91 males and 37 females, 82 cases of the left hip and 75 cases of the right hip; ranging in age from 22 to 78 years old, with a mean of 55.1 years old. The abduction angle(β), ilium thickness (a), acetabular cup insertion depth (b), ischial thickness (c), acetabular cup insertion depth(d), acetabular abrasion and contusion depth(e) were measured on the postoperative AP X-ray of both hips, and the data were compared.@*RESULTS@#There was a positive correlation between β and b (=0.424, =0.000), a negative correlation between β and d (=-0.407, =0.000), a positive correlation between β and b/a (=0.419, =0.000), a negative correlation between β and d/c (=-0.472, =0.000). There was a linear relationship between β and b/a (5.753, =0.000) and a linear relationship between β and d/c (-6.671, =0.000).@*CONCLUSIONS@#The outreach angle is mainly controlled by the distance between the outer edge of the cup and the outer edge of the cup in the inferior portion(d) during the operation. The distance b from the outer edge of the cup can be used as a reference.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Postoperative Period , Radiography
4.
China Journal of Orthopaedics and Traumatology ; (12): 791-794, 2016.
Article in Chinese | WPRIM | ID: wpr-230394

ABSTRACT

<p><b>OBJECTIVE</b>To reveal the characteristics of anatomical and mechanical axes in lower extremities by analyzing full length weight bearing X ray radiographsin patients with knee osteoarthritis(OA).</p><p><b>METHODS</b>From June 2015 to May 2016, the lower extremity CTA was performed for 20 patients with vascular diseases, and these patients without OA were assigned to the normal group. There were 7 males and 13 females, ranging in age from 24 to 72 years old with an average age of 63.2 years old. The weight bearing full length X ray radiographs of the lower extremities were taken for 53 patients with knee OA, and these patients were assigned to the OA group. There were 10 males and 43 females, ranging in age from 52 to 80 years old with an average age of 64.7 years old. The osteoarthritis group were divided into two groups:varus knee group and valgus knee group. The femoral shaft double condyle angle(F), tibial shaft plateau angle(T), joint gap angle(JS), femoral tibial angle(FT), hip knee ankle angle(HKA), knee physiological valgus angle(KPV), and femoral offset were measured. The SPSS 21.0 was used to analyze the statistical data.</p><p><b>RESULTS</b>The mean F were (79.9±2.3)° and (81.4±3.5)°, T were (93.8±3.7)° and (94.6±2.7)°, JS were (1.7±1.0)° and (2.1±2.5)°, FT were (175.4±4.0)° and (178.1±6.3)°, HKA were (181.4±4.1)° and (184.3±6.9)°, KPV were (6.0±1.0)° and (6.2±1.5)°, offset were (38.5±6.5) mm and (38.1±9.2) mm in the normal and OA group respectively. There was a significant difference in the KPV between varus knee and valgus knee groups(=2.956,=0.005), and the greater mean KPV was found in varus knee. Positive correlations were found between KPV and age(=0.241,=0.016), as well as between KPV and offset (r=0.946,=0.000).</p><p><b>CONCLUSIONS</b>The average KPV in patients with knee OA was 6.2° in the present study, and the KPVs were also positively correlated with the patients' ages and the femoral offsets. The average KPV in the varus knee was greater than that of the valgus knee, and the difference was about 1°. The changes of mechanical parameters of lower limb may be one of the risks for developing knee OA. Analyzing the full length weight bearing X ray radiographs of the lower extremities preoperatively will be helpful to determine a individualized osteotomy method for patients.</p>

5.
China Journal of Orthopaedics and Traumatology ; (12): 102-106, 2016.
Article in Chinese | WPRIM | ID: wpr-304337

ABSTRACT

<p><b>OBJECTIVE</b>To introduce a new measuring tool for measuring postoperative limb length exactly, and to provide a convenient and effective method to control limb length after total hip replacement.</p><p><b>METHODS</b>From January 2013 to September 2014, 102 patients undergoing primary unilateral hip replacement were divided into two groups: experimental group and control group. There were 51 patients in the experimental group, including 25 males and 26 females, ranging in age from 37 to 92 years old, with an average of 60.41 years old. The patients in experimental group were treated with new method to control limb length. Other 51 patients in the control group, including 27 males and 24 females, ranging in age from 35 to 87 years old, with an average of 61.00 years old. The patients in the control group were treated with normal methods such as shuck test or limb touching. All the patients were operated by the same experienced surgeon. In the experimental group,total hip arthroplasties (THA) were performed on 35 patients with avascular necrosis of the femoral head or femoral neck fracture, and 16 patients were treated with hemiarthroplasty (HA). In the control group, 38 patients received THA and 13 patients received HA. On the anterior-posterior X-ray radiograph, several indexes were measured as follows: the distance of bilateral femoral offset (a), the height from tip of great trochanter to the rotation center of the femoral head (b) and the vertical distance between the top of the minor trochanter and the two tear drops line (c). The leg length discrepancy can be assessed with three parameters as follows: d1, the absolute value of the difference between the bilateral a values; d2, the difference between the bilateral b values; d3, the difference between the bilateral c values. The SPSS 21.0 was applied for the statistical analysis.</p><p><b>RESULTS</b>In the experimental and control groups, d1 were 4.49 mm and 7.32 mm (P = 0.013); d2 were 2.37 mm and 4.32 mm (P = 0.033); d3 were 3.32 mm and 6.08 mm (P = 0.031). The values of d1, d2 and d3 in the experimental group were significant smaller than those in the control group.</p><p><b>CONCLUSION</b>The new measuring tool and method can be used to control the limb length and offset effectively during operation.</p>


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Methods , Case-Control Studies , Leg Length Inequality
6.
Chinese Medical Journal ; (24): 1579-1583, 2015.
Article in English | WPRIM | ID: wpr-231731

ABSTRACT

<p><b>BACKGROUND</b>Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC.</p><p><b>METHODS</b>A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section.</p><p><b>RESULTS</b>At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome.</p><p><b>CONCLUSIONS</b>HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Cross-Sectional Studies , Hip Prosthesis , Ilium , Diagnostic Imaging , Radiography